进口食品连锁便利店专家团队...

Leading professional group in the network,security and blockchain sectors

CS-105 - Train Control Systems Documentation

Issac79094498893378 2025.04.12 10:34 查看 : 2

Depending on the installation and utilization circumstances, the cables in operation start deteriorating from the time of preliminary operation. Inspect your LCC cables between the CS-105 and your booster community. The LCC Booster output is disabled. Remove the quick-circuit. Check for derailed trains, incorrectly lined turnouts, reversing loop polarity, or wiring problems, resembling a locomotive bridging to an incorrectly wired neighboring booster district. No locomotive is chosen. 4. If the CS-105 is lacking, then confirm the connection between JMRI and the CS-105. 3. If the UWT throttle is lacking, then probably your throttle is related to the wrong WiFi network. The CS-105 is in Access Point Mode, and your throttle is linked to the wrong WiFi network (not the CS-105). Full Instructions with pictures on the right way to replace your CS-105 through JMRI using WiFi may be discovered on the TCS Website. If TCS DEPOT just isn't supported on your Pc, continue studying beneath or visit the TCS webpage for different directions. See the instructions under "Push Button Configuration Mode" part "WPS" subsection.



stockillustraties, clipart, cartoons en iconen met electric heater and air conditioning - cv power cable If you end up locked out, cv power cable use the push button configuration method to change the CS-105 to Access Point mode. The programming track is disabled by configuration. The CS-105 has overheated and disabled energy output for security. Note: Uplink is disabled by default. Saved Networks. Pick the community title that the CS-105 broadcasts (default LAYOUTWIFI). In recent years, WiFi mesh community solutions have turn into extra prevalent. These information have the extension ".bin" Firmware recordsdata may be downloaded from the Firmware Page on the TCS Website. TCS throttles can sometimes detect the presence of the CS-105, but remember the last IP handle for faster connection. The CS-105 and TCS Wireless throttles use 2.4GHz WiFi, which gives better vary and penetration by means of obstacles akin to walls or benchwork. The CS-105 deliberately uses 2.4GHz WiFi to realize most range. Remove both the WiFi or the wired connection between JMRI and the CS-105. This happens when the CS-105 is connected to JMRI by way of both WiFi and the LCC CAN-bus cable, and a loop is created in the LCC community. The WiFi Full LED is on.



The Track LED and the WiFi Full/Error LED are quickly blinking in an alternating trend. A WiFi entry point connected and paired to the computer and the CS-105. The overwhelming majority of model railroad layouts do not require more than one WiFi Access Point. For that reason, it's endorsed to set your WiFi router to at all times assign a set (static) IP tackle to the command station. If it doesn't work, then it's possible you'll must manually set the IP address of the CS-105 on the throttle. In twin throttle mode on the UWT-100, it's all the time the left-hand throttle that's used for Roster Settings. The throttle is set to function in WiThrottle Protocol mode. Uplink - Allows you to attach the Command Station to a LCC-enabled router for the categorical goal of increasing the variety of possible wireless LCC throttle connections without the necessity for a Pc and/or JMRI server connection.



It's good to obtain and apply a correct software program replace. You at the moment are in bootloader mode, you might be prepared to start the firmware update process! The CS-105 is in bootloader mode. To exit bootloader mode, take away the ability from the CS-105, wait two seconds for all lights to go out, then plug in power once more. Remove power, wait at least 5 seconds, and reapply energy. The LCC Network is missing terminator(s) To perform properly, the wired LCC network requires at least one terminator. Problem: The LCC-USB adapter has its lights blinking rapidly, and in JMRI’s LCC Connection Monitor there are many quick messages scrolling sooner than I can read. You could must temporarily unplug the USB-LCC adapter from your pc, stop JMRI, or swap the CS-105 into Access Point mode to let the LCC network get better. Set IP tackle. Enter the IP tackle (often the primary three numbers are pre-stuffed for you and you only must enter the last quantity) and press Save. You need an LCC hub / repeater to connect greater than 10 WiFi throttles in WiFi Client mode. To use a UWT with the CS-105, the LCC mode ought to be selected.